With a temperature measurement range that surpasses boiling points, the possibilities are endless. Keep holding the trigger as you move the Lasergrip if you wish to live scan the surface area for temperature measurement. 1x 9V DC Battery. 1x Etekcity Lasergrip 1022D Thermometer . • DO NOT attempt to point laser-light at an aircraft. Please Wait 10 seconds. Non-reflective surfaces have a higher emissivity (closer to 1) than reflective surfaces (closer to O). Laser radiation may cause damage to eyes. "; } }, 1000); }; var clickbtn = document.getElementById("btn"); clickbtn.onclick = startDownload; PDF Content Summary: Accordion Fold ETEKCITY Thank you for purchasing the Lasergrip 1022 Infrared Thermometer by Etekcity. Laser Pointer / UP 4. 1. This easy-to-use device lets you conveniently and accurately measure surface temperatures from a distance without the need of any direct contact. 3. Reliable Product This is a big seller in Amazon and many respected institution like Car Magazines, Airports, Universities purchase this product from us! Immediately replace the battery when the icon appears. • In the vicinity of use, make any bystanders aware of the dangers of looking directly into the laser pointer. D Material Emissivity Of Articles Feature Emissivity Material Oxidized 0.3 Human skin Polished 0.02-0.04 Graphite Feature Emlselvity INFRARED THERMOMETER (-'F-1022*F/4-60*c-350 THIS PUTOVA1914*W6T. A laser light aids in aiming, and can be turned on or off. Find how-to videos, manuals, and other helpful instructions.Smart WiFi Outlet Support. LASERGRIP1022 Infrared Thermometer Laser Activation To activate and deactivate the laser, press the laser pointer On/Off button at any time while the Lasergrip is on. You deserve it! © 2016 Etekcity Corporation.All Rights Reserved, Ready to use our new smart WiFi outlets? Post was not sent - check your email addresses! Please contact us Mon-Fri 9:00 AM - 6:00 PM PST at (855) 686-3835 or email support@etekcity.com Safety Use & Care • DO NOT point the laser-light at another person or animal. °C/°F Temperature Result 7. These documentations are only intended for qualified technicians who are aware of the respective safety regulations. Products names, logos, brands and other trademarks are the property of their respective trademark holders in the USA and other countries. Do not use the Lasergrip as a reliable source to measure body temperatures. DO NOT AIM LASER-LIGHT AT ANOTHER PERSON OR ANIMAL, LASER RADIATION MAY DAMAGE YOUR EYE. Max Temperature / Emissivity Result 8. Clear text displays the measured temperature in either Celsius or Fahrenheit. Wood 0.90-0.95 Textile powdered 0.96 Paper 0.95 PAIR Polarity facing upward Charcoal Carbon 0.85 Sand 0.90 0.92-0.96 To take accurate temperature measurement of reflective surfaces with low emissivity, place a strip of black masking tape over the surface and allow for it to adjust to the temperature of the surface for approximately 30 minutes. Point the Lasergrip towards the surface of measurement. This creates a spot measurement area of 1.18 inches (3 cm) in diameter. The measured temperature for humans or animals will not be correct. • Avoid direct/indirect eye contact with the laser-beam. Please contact us Mon-Fri 9:00 AM - 6:00 PM PST at (855) 686-3835 or email support@etekcity.com visit etekcity.com for more products. -1 - 2 - - 4 Battery Replacement Distance (D) to Spot (S) size D:S = 12:1 ETEKCITY LASERORP10722 The device certification information is labeled directly on the device. Besides, the steam, dust, smog will lower the accuracy of testing. components. It makes for better accuracy and easier operation. This means you may measure the temp of a smaller area at the same distance compared to other 8:1 thermometers; thus the readings are much more accurate! THE LASER LIGHT IS INVISIBLE TO THE HUMAN EYE. - 5 - -6 -7 -8. 0.80-0.90 Mortar 0.95 Brick DETEKCITY Asphalt 9V 6F22 or 6LR61 Battery 0.90-0.96 Rock 0.7 Marble Wiring is not bulging out of the compartment 0.94 0.90 a simpler life starts here. • The thermometer measures surface temperature, not internal temperature. User Manual Questions or Concerns? It turns on and begins reading the temperature with one press of the trigger. This Etekcity non-contact IR temperature gun is easy to operate. Unit (°C/°F) / DOWN 5. Including interference that may cause undesired operation. Get our exclusive deals and news on the latest products. 10 Plastic cement Oxidized 0.7 Concrete 0.70-0.90 Cement 0.95 Steel 0.96 M. .17 ded ETERSITY SAPORATION * கலாக HWOO NWALD CAUTION Asbestos 0.95 Soil 0.90-0.98 Any updates to the product information (date of manufacturing and manufacturer address) will be added as adhesive overlays. Plaster 0.89-0.91 Emissivity The emissivity of a material is its efficiency in emitting thermal energy. Connect a new DC 9V battery, making sure it's under the correct polarity. This thermometer cannot test the temperature of target objects through across the glass. Besides, the steam, dust, smog will lower the accuracy of testing. As the distance between the thermometer and the surface increases, the total surface area measured will also increase. • DO NOT use leaking batteries or dispose old batteries in fire. 3. Low Battery 2. Display Backlight On/Off 3. 6. Press and hold the measurement trigger and the laser will activate for aiming guidance. By continuing to browse the site you are agreeing to our use of cookies. (See Page 7 for details) 0.9 0.85-0.92 Lacquerwork lackluster 0.97 Clay Carbon Cement 0.90 Sand Soap Bubble 0.75-0.80 Glass Water 0.93 Textile Snow 0.83-0.90 Heated food Ice 0.96-0.

.

Lithium Oxide Reacts With Water Equation, Zoom H4n Pro Manual, Australian School Subjects List, Denon Audyssey Reference Vs Flat, Decomposition Of Silver Chloride In Sunlight, The Power Of Project Leadership'' Susanne Madsen, Antique French Grain Sacks, Jbc Reviews Impact Factor, Fastest Electric Car In The World 2020, Copperplate Gothic Windows 10,